RaySafe i3

Real-time Personal Radiation Dosimetry

Manage your radiation exposure instantly

Learn how the new RaySafe i3 system gives you immediate X-ray exposure information.
Download brochure »

Applications for i3

RaySafe i3, building a better radiation safety culture

The Raysafe i3 system is the latest generation of the real-time dosimetry family. The system includes a set of the new RaySafe real-time personal radiation dosimeters coupled with a display and software to provide with a complete, immediate visual of radiation exposures.

Visualize X-ray exposure with the new i3 real-time personal radiation dosimeter using easy-to-read bar graphs. Instant feedback empowers your medical staff to learn and adapt their behavior on the go, minimizing unnecessary radiation exposure.

Measurements are simultaneously stored for post-procedure analysis, facilitating continued learning and to enable comparisons over time, between labs and between users.

Overview i3

Features and benefits

RaySafe i3 offers the following important benefits

Replaceable battery prolonged life cycle

The new Real-time Dosimeter has a replaceable battery, which means that longevity depends solely on wear and tear.

Better immunity to interference

RaySafe i2 dosimeters are sensitive to certain cell phone signals. The new Real-time Dosimeter is greatly improved in this regard no interference has been observed during heavy testing.

Automatic sleep mode

Only active dosimeters will populate the screen, regardless of where the inactive units are stored.

Enhanced measurement performance

Wider angular response means that radiation coming from below and from the sides is measured in a predictable fashion. Lowered dose rate threshold results in improved response when used with the latest low dose X-ray machines.

    Sensor Response

Detailed comparison

RaySafe i3 Dosimeter RaySafe i2 Dosimeter
FUNCTIONALITY
Radio communication Frequency depending on region
Compatible with existing real-time dosimetry products
Energy saving features Longer transmission intervals
when not irradiated,
automatic sleep mode
Longer transmission intervals when not irradiated
PC connectivity Micro USB connector USB docking cradle
Battery User replaceable, non rechargeable Non replaceable, non rechargeable
DESIGN
Pocket clip Plastic clip, user replaceable Metal clip, non replaceable
Visual feedback LED error and wake up indication LED error indication
TECHNICAL SPECIFICATION
Energy range N40 - N150 N40 - N120
Dose rate uncertainty ±10% or 10 µSv/h (40 µSv/h 150 mSv/h)
±20% (150 mSv/h 300 mSv/h)
±40% (300 mSv/h 500 mSv/h)
±10% (40 µSv/h 150 mSv/h)
±20% (150 mSv/h – 300 mSv/h)
Angular dependency < 5% (0° 10°)
< 30% (10° 60°)
+30% to -100% (60° 90°)
< 5% (0° 5°)
< 30% (5° 50°)
+200% to -100% (50° 90°)
Expected longevity Up to 10 years 3-5 years, until the battery runs out

Radiation Safety

Radiation protection is important because:

  • Radiation exposure from medical procedures has increased dramatically during the last few years

  • radaition exposure

  • Interventional cardiologists receive the highest amounts of radiation among medical personnel

  • scatter radiation

  • Radiation exposure can be reduced significantly by optimizing behavior and by using protective devices

  • radiation safety equation

ABCs for a Radiation Safety Culture™

Avoidance

Avoidance

Protective clothing and devices, such as lead aprons, thyroid collars, glasses, ceiling suspended screens and table-mounted lead curtains, are the first line of defense against radiation exposure. Personal dosimeters are used to monitor and help regulate exposure.


Behavior

Behavior

Your behavior will affect your radiation exposure. When feasible, increase the distance and decrease the exposure time. Furthermore, scatter radiation is typically lower on the detector side.

Finally, ensure that the proper equipment and appropriate techniques are used, including collimating the X-ray beam.


Control

Control

Ultimately, controlling your dose is easiest when it is known. Only an active dosimeter, such as RaySafe i3, provides constant, real-time radiation exposure information. With the information it provides, healthcare workers can take action to reduce their dose.


Scatter Radiation


"The improvement in radiation protection has been more than dramatic at the URMC. There is no substitute for a constant and real-time reminder of the dose being received."
-Labib H. Syed, M.D., M.P.H.
University of Rochester Medical Center


"We feel better about our work and our safety. Now that we see what RaySafe real-time dosimetry does for us, we wouldn’t want to work at a place that doesn’t have it.”
-Dawn Dowling, Technologist
Lawrence General Hospital


Contact us

Contact

Please contact us for more information.

Contact

Radiation Safety Culture

Radiation Safety Culture Behaviour

The ABCs for a
Radiation Safety Culture

Read more

Related content